Preview

Legal regulation in veterinary medicine

Advanced search

The effect of the height of filling the tubes with blood on the quantitative indicators of the resulting platelet plasma

https://doi.org/10.52419/issn2782-6252.2023.4.161

Abstract

The relationship between the height of filling of test tubes with blood and quantitative indicators of platelet plasma obtained by centrifugation was studied on blood samples of Wistar rats. The test tube filling height of 6.0 cm and 3.0 cm was chosen as the comparison criteria. In combination with another criterion, such as the volume of blood placed in a test tube, a total of four (4) variants of platelet plasma production were investigated and analyzed. In the first variant (No. 1), the tubes contained 4.0 ml of blood, the height of filling the tubes was 6.0 cm. In the second variant (No. 2), the tubes contained 2.0 ml of blood, the filling height of the tubes was 3.0 cm. In the third variant (No. 3), insulin syringes were used, which contained 1.0 ml of blood, their filling height was 6.0 cm. In the fourth variant (No. 4), insulin syringes were also used, which contained 0.5 ml of blood, their filling height was 3.0 cm. All test tubes/syringes were centrifuged in the same mode (3000 rpm – 1.0 min + 1000 rpm – 10.0 min) on an OPN-3 centrifuge with a bucket rotor. Further, the concentration of platelets in the separated plasma was immediately determined at different distances from the upper layer of the erythrocyte sediment. Then the plasma was completely sampled, the platelet concentration and its volume were determined.
The results were processed by methods of variational statistics. Analysis of the results showed that in variants No. 1 and No. 3, the concentration of platelets in the resulting plasma was almost 30% and 10% higher than in variants No. 2 and No. 4, respectively. Considering that the total amount of plasma obtained, expressed as a percentage relative to the initial amount of blood, was approximately the same in all variants, it can be concluded that a higher level of filling of test tubes with blood before centrifugation makes it possible to obtain plasma more saturated with platelets.

About the Authors

A. V. Bokarev
St. Petersburg State University of Veterinary Medicine
Russian Federation

Alexander V. Bokarev, Dr.Habil. in veterinary sciences, Docent



A. O. Minina
St. Petersburg State University of Veterinary Medicine
Russian Federation

Anastasia O. Minina, PhD of Veterinary Sciences, Docent



R. D. Kholodny
St. Petersburg State University of Veterinary Medicine
Russian Federation

Ruslan D. Kholodny



E. Ya. Pilipets
St. Petersburg State University of Veterinary Medicine
Russian Federation

Elizaveta Ya. Pilipets



References

1. Boyeykov, V.L. Blood as an active colloid. Nonlinear effects observed during sedimentation of blood diluted with physiological solution / V.L. Boyeikov, E.V. Buravleva, S.E. Kondakov // Bulletin of Moscow University. - Episode 2: Chemistry. - 2012. - T. 53. - No. 6. - P. 413-416.

2. Kondakov, S.E. Sedimentation of blood cells. Model of an active colloidal system / S.E. Kondakov, M.Ya. Melnikov, A.A. Tokarev // Bulletin of Moscow University. - Episode 2: Chemistry. - 2008. - T. 49. - No. 4. - P. 238-240.

3. Lipunova, E.A. Physiology of blood: monograph / E.A. Lipunova, M.Yu. Skorkina. - Belgorod: BelSU Publishing House, 2007. - 324 p. - ISBN 978-5-9571-0305-9.

4. Ineffective Plasmolifting. Gel is evil // Cross D: [website]. - 2018. - URL: https://cross-dental.com/ru/posts/2765747/ (access date 11/05/2023).

5. Optimization of the method of obtaining platelet-rich plasma (PRP) from the blood of horses / A.Yu. Zakharov, A.V. Bokarev, A.A. Stekolnikov [et al.] // Issues of legal regulation in veterinary medicine. - 2020. - No. 4. S. - 89-92.

6. Sulaeva, O.N. Obtaining platelet-rich plasma: myths and reality / O.N. Sulaeva // World of medicine and biology. - 2017. - T. 13. - No. 3 (61). - P. 150-153.

7. Frimel, G. Immunological methods: monograph / G. Frimel - Moscow: “Medicine”, 1987. - P. 226-254.

8. Kheifets, L.B. Separation of human blood cells in a verografin-ficoll density gradient / L.B. Kheifets, V.A. Abalakin // Laboratory work. - 1973. - No. 10. - P. 579-581.

9. Effect of anticoagulant type and centrifugation speed on platelet-rich plasma of cats and dogs blood / M. Sverdlova, A. Zakharov, A. Stekolnikov [et al.] // EurAsian Journal of BioSciences. - 2020. - Т. 14. - № 2. - С. 7589-7593.

10. Platelet-rich plasma and platelet gel: a review / P.A .Everts, J.T. Knape, G. Weibrich [et al.] // The journal of extra-Corporeal Technology. - 2006. - № 38(2). - P. 174-187.


Review

For citations:


Bokarev A.V., Minina A.O., Kholodny R.D., Pilipets E.Ya. The effect of the height of filling the tubes with blood on the quantitative indicators of the resulting platelet plasma. Legal regulation in veterinary medicine. 2023;(4):161-166. (In Russ.) https://doi.org/10.52419/issn2782-6252.2023.4.161

Views: 115


Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 License.


ISSN 2782-6252 (Print)